Ürün ayrıntıları:
|
Port Boyutu: | 5,08 mm | Kabuk malzemesi: | silikon |
---|---|---|---|
Maksimum Çalışma Sıcaklığı: | + 85 °C | Asgari Çalışma Sıcaklığı: | - 25 ° C |
Maksimum Güç Kaynağı Voltajı: | 15V | Minimum Güç Kaynağı Voltajı: | 8V |
Vurgulamak: | YJJ AWM2100V gas flow sensor,HVAC control air flow sensor,medical analog flow sensor |
Product Description:
YJJ AWM2100V Gas Mass Flow Sensor Has An Analog Output Of ±200 Sccm And Is Used For HVAC Control
Features:
AWM2000 series gas mass flow sensor, non-amplified (mV), flow/pressure range: ±30.0 sccm; straight port type.
The AWM2000 series microbridge gas mass flow sensor is a passive device composed of two Wheatstone bridges. According to the operating specifications, a heater control circuit is also required. According to the operating specifications, a sensing bridge power supply circuit is also necessary. These two circuits are not on the packaged circuit board, so they must be provided in the application. The differential amplifier is a useful interface for the sensing bridge. It can be used to increase gain and introduce voltage bias into the sensor output.
Application: Dry Gas
Range: +/- 200 cm/min
Accuracy: 0.35 %
Output Voltage: 30 mV
Operating Power Supply Voltage: 8 V to 15 V
Port Size: 5.08 mm
Shell Material: Silicon
Trademark: Honeywell
Maximum Operating Temperature: + 85 °C
Minimum Operating Temperature: - 25 °C
Product Type: Flow Sensors
Series: AWM200 5
Subcategory: Sensors
Maximum power supply voltage: 15 V
Minimum power supply voltage: 8 V
Unit weight: 10.800 g
The Honeywell AWM2000 series gas mass flow sensor is a device that utilizes a silicon film and an insulated microbridge structure. Within its microstructure, there are heaters and temperature sensing elements. This bridge-type sensor can respond sensitively and rapidly to changes in the flow rate of air or other gases beneath the diaphragm. This series of products adopts advanced design and manufacturing techniques. Its microbridge structure is not only small in size but also has extremely sensitive and rapid response capabilities. It is suitable for any situation where gas flow monitoring is required.
Product damage
The AWM series micro bridge type gas mass flow sensor is not suitable for measuring liquid flow. When liquid flows through the sensor, it will damage the sensor.
Failure to follow these instructions may result in damage to the product.
Product Features
Bidirectional airflow sensing
Measurement of actual gas mass flow
Low differential pressure measurement
Product Application
HVAC air valve and damper control
Gas analyzer
Low vacuum control
Medical ventilator
Anesthesia machine
Gas calibration
Specifications:
Application | Dry Gas |
Range | +/- 200 cm/min |
Accuracy | 0.35 % |
Output Voltage | 30 mV |
İlgili kişi: Miss. Xu